Re: New Acurite radiation shield for the tower and lightning detectors
Quote from: sundevil01010101 on Today at 11:07:44 AMThat's a great add to their product line...Now if only:1. You could submit the shielded tower's temperature and/or humidity sensors instead of the...
View ArticleRe: New Acurite radiation shield for the tower and lightning detectors
You can use a Meteobridge to min 'n match, too. I use my shielded tower to report temp/humidity/dew point and the 5in1 for wind & rain. Pressure, of course, comes from the hub itself.
View ArticleRe: 5n1 Humidity Sensor Replacement
I'm about to do the same repair. The 5-n-1 has a soldered ribbon cable. What's the collected wisdom on the best way to do it:replace jumper cable on the temperature sensor board with the ribbon...
View ArticleRe: 5n1 Humidity Sensor Replacement
Quote from: rct on Today at 05:53:21 PMI'm about to do the same repair. The 5-n-1 has a soldered ribbon cable. What's the collected wisdom on the best way to do it:replace jumper cable on the...
View ArticleRe: 5n1 Humidity Sensor Replacement
I decided to check mine out since my humidity is not going up & down like it should be compared to my acurite tower and Oregon 100. Everything looked really good, and I took a pic while I was in...
View ArticleRe: 5n1 Humidity Sensor Replacement
I've somewhat successfully replaced the temp/humidity sensor in my 5n1 without the pins. It's easy to see why the temp/humidity board failed since the traces have been eaten through. See attached....
View ArticleRe: 5n1 Humidity Sensor Replacement
Forgot to mention a tip for others attempting the same repair. The pins are in the same order on the replacement board. Both have the pins labeled. The pins on the exposed side of the main board...
View ArticleRe: New Acurite Lightning Detector
Capturing the text output is good as it's printing all the raw bytes on each line. I tend to use either `script -af file` to capture everything or:Code: [Select]rtl_433 -q -p NN -R 39 2>&1 |...
View ArticleRe: New Acurite Lightning Detector
The attached file is actually in gzip format, not zip, so I could attach it.Starting temp about 79F, placed in freezer at about 5F for about 10 minutes or so.At top of the hour removed from freezer and...
View ArticleRe: New Acurite Lightning Detector
George, thanks for the data. So in the 5th byte of your data, the byte that I think is the status/message type, I only see 5 values, which isn't enough range for temperature. 1st column is number of...
View ArticleRe: New Acurite Lightning Detector
I went and checked the data I've been logging over the last few weeks. I found some similar status bytes to George's that I wasn't expecting (values where the lower nybble isn't 0 or 1.Code: [Select]...
View ArticleRe: New Acurite Lightning Detector
As far as the count goes, it's always been 5. I started reading it soon after putting in the batteries, so maybe that's from factory testing.I haven't heard it beep or anything like that since I got it.
View ArticleRe: 5n1 Humidity Sensor Replacement
My 5 in 1 just failed for the same problem.The root cause of the problem was not the chip. It's the trace that had developed an open circuit from corrosion. I just soldered on a tiny shunt wire from...
View ArticleRe: 5n1 Humidity Sensor Replacement
Quote from: davefr on Yesterday at 02:36:35 PMMy 5 in 1 just failed for the same problem. [...] It looks like AcuRite didn't do a very good job sealing that circuit board.FWIW, the replacement boards...
View ArticleRe: 5n1 Humidity Sensor Replacement
Quote from: rct on Yesterday at 03:04:13 PMQuote from: davefr on Yesterday at 02:36:35 PMMy 5 in 1 just failed for the same problem. [...] It looks like AcuRite didn't do a very good job sealing that...
View ArticleRe: Myacurite reports wrong pressure when everything else is correct??
Quote from: nincehelser on October 27, 2016, 02:54:11 PMQuote from: davefr on October 27, 2016, 02:51:41 PMMy display reports the correct barometric pressure. (ie 29.88" HG)Wunderground is also...
View ArticleRe: Myacurite reports wrong pressure when everything else is correct??
Quote from: davefr on October 27, 2016, 03:06:55 PMQuote from: nincehelser on October 27, 2016, 02:54:11 PMQuote from: davefr on October 27, 2016, 02:51:41 PMMy display reports the correct barometric...
View ArticleRe: Myacurite reports wrong pressure when everything else is correct??
Quote from: davefr on October 27, 2016, 03:11:11 PMStation PressureThat would mean you're sending station pressure to wunderground (and myAcurite). Wunderground has apparently turned on their own...
View ArticleRe: Myacurite reports wrong pressure when everything else is correct??
^^Thank you. I think I understand now.
View Article